Photo Credit: Hiberatlas
Info extracted from Hiberatlas.
Principle Characteristics of the Building:
Ownership type: | Private |
Year of construction: | 1900-1944 |
Floor area after works: | 1100 m² |
Structure: | Stone walls of 60 cm were insulated from the inside with 20 cm of mineral wool. |
Heating and energy: | Replacement of the oil boiler dating from 1982 with a 40 kW wood boiler located outside the heated volume. Installation of 2 wood pellet boilers and heated floor on the ground floor – low temperature radiators in offices. Installation of two double-flow mechanical ventilation systems with an exchanger efficiency of 81%. |
Energy performance: | Heating: Consumption_estimation_Before: 374,2 kWh/m2.y; Consumption_estimation_After: 88,6 kWh/m2.yPrimary Energy: Consumption_estimation_Before: 374,2 kWh/m2.y; Consumption_estimation_After: 88,6 kWh/m2.y |
Cost of works: | €1,240,000 |
Architect: | Tandem Agence, Dreux |